SuperCure & SuperCure Q

Price
6,000 IQD

Product Information

  • Build a high-strength core faster with SuperCure, light activated composite core buildup material. Inject direct from the SuperCure syringe tip into the tooth. Light activate to a dentin-like hardness for immediate prep. Easier, faster, better.

    SuperCure is available in two high performance formulations.

    Original SuperCure – with barium borosilicate glass filler cuts like dentin.

    SuperCure-Q – is reinforced with quartz glass filler to cut harder than dentin.

    Both formulations are packaged in Centrix exclusive direct-to-the-tooth unit-dose tips (.25gm or .50gm) with enough material to meet the needs of most buildups.

    Just place a tip of SuperCure light-activated core buildup material in your Centrix syringe and inject. There’s no mixing, no wasteful automix nozzles and no cross-contamination. SuperCure stacks beautifully, without slump, so matrices or coreforms are not required.

    • Original formula of barium borosilicate glass filler cuts like dentin
    • Q-formula is reinforced with quartz glass filler to cut harder than dentin
    • Fast light-activation and high depth of cure: 8.9mm in 40 seconds
    • Disposable, prefilled tips for maximum asepsis
    • Non-slumping formula requires no matrix
    • Prefilled tips eliminate mixing, cleanup and waste
    • Radiopaque

    All kits contain 30 tips.

    Specifications

    Original SuperCure

    Compressive strength
    235 Mpa

    Diametral tensile strength
    50 Mpa

    Flexural Strength
    87 Mpa

    Filler type
    Barium Borosilicate Glass

    Cure depth, (ADA), 40 seconds
    8.9mm

    SuperCure Q

    Compressive strength
    207 Mpa

    Diametral tensile strength
    87 Mpa

    Flexural Strength
    104 Mpa

    Filler type
    Quartz Glass

    Cure depth, (ADA), 40 seconds
    8.9mm

    How To's

    SuperCure

    DO NOT USE IN THE PRESENCE OF EUGENOL!

    Do not use on patients with known allergies to Bis-GMA, benzoyl peroxide or other components.

    1. Isolate the tooth with a rubber dam or cotton rolls.
    2. Remove all decay and existing restorative materials, including eugenol cements or sealers.
    3. Place an adhesive bonding agent system for dentin that is compatible with light-activated composites. Follow manufacturers’ specific instructions for use.
    4. Remove cap (or sheath) and insert the SuperCure tip into a Centrix C-R syringe.Test flow by expressing a small amount of material onto a pad.
    5. Inject a 2mm layer of material into the prep, over the surface coated by the bonding agent. Light-activate for 20 seconds, using any halogen, LED or PAC light source.
    6. Place a second layer on top, not to exceed a thickness of 6 to 8mm. Light activate for 40 sec.
    7. Cut and prep the core, using water-cooled diamonds or burs.